Real process extract is rarely one gas. When the stream carries acidic and alkaline components together, or a particulate load ahead of a soluble gas, a single stage forces a compromise — and the compromise is always paid for in outlet concentration.

  • Mixed acid gases
  • NH₃ with HCl
  • Particulate with soluble gas
  • Solvent mists
  • H₂S

The principle

Staging removes that compromise. Each stage runs its own liquor circuit, its own chemistry and its own control loop, and each is sized for the fraction of the duty it actually has to do.

Stages are ordered by what protects what: particulate removal ahead of any packed bed, acid before alkaline where ammonia is present, and oxidant last where the residual is a trace sulphur compound.

Independent liquor circuits

Separate sumps, pumps and dosing per stage. Nothing cross-contaminates, and one stage can be taken down for service without losing the other.

Staged sizing

Each stage is calculated for its own share of the removal, so you are not paying for bed depth that is doing nothing.

Interstage sampling

Sample points between stages, so performance can be proved stage by stage at commissioning and during operation.

One control system

All stages on a single panel with a common alarm and BMS interface, rather than a set of unrelated skids.

Specification

Design envelope

Indicative ranges for this system type. Your figures are calculated against your duty and issued on a datasheet before anything is built.

Multi-stage scrubbers
Duty range500 – 50,000 m³/h
StagesTwo or three, in series, each independently controlled
Typical stage 1Particulate removal or acid stage for alkaline gases
Typical stage 2Caustic stage for acid gases
Typical stage 3Oxidant stage or activated carbon polishing
Body materialsPP, PVDF, GRP or 316L, selected per stage
Overall removal99%+ achievable on mixed soluble streams
SamplingIsokinetic-capable sample points at inlet, interstage and discharge
Compliance

What it is built to

Equipment is one part of a duty holder's obligations. These are the standards and regulations we design this system type against — your own risk assessment and permit conditions still govern.

  • Performance demonstrated stage by stage at commissioning, against an agreed test method
  • Reagent systems segregated, bunded and separately labelled
  • DSEAR and ATEX assessment where solvent or flammable gas is present
  • UKCA marked; supplied with a full O&M manual and P&ID set

Tell us the duty and we will size it

Send the gas composition, the flow and the discharge condition you have to meet. We will come back with what will work and what it will take out — and say so plainly if this is the wrong system for the job.